DMM VCA CAN

Flow computer

Categorie , Tag

Description

Abbinamento automatico con sensore di flusso

Elaborazione dati in tempo reale

Fino a 10 curve fluide personalizzate selezionabili

 

 

 

 

 

 

 

 

 

Specifiche

  • Input signals Flow meter pulses 2.5 kHz TTL max. Media temperature digital
  • Output signals (linearised & viscosity corrected) CAN 2.0B high Speed (ISO 11898-2:2016)
  • Baud Rate: 10kBit/s up to 1MBit/s
  • Flow rate metrological properties Accuracy ± 0.1 % transmit cycle ≥ 1 ms Low flow cut off 0.6 to 5 s
  • Adjustable filtering 0 to 5 s
  • Temperature properties Resolution 0,25 °C Sampling rate 0.5 s
  • Custom fluid characteristics Up to 10 fluid curves, 29 points each (RFID-Tag selectable)
  • Supply voltage 9 to 32 V DC reverse polarity protected
  • Power consumption ≤ 60 mA
  • Degree of protection IP 67
  • Operating temperature range −40 °C to +125 °C
  • Electrical connections LEMO/Yamaichi size 0
  • EMC EN 55011 EN 61000-4-2 bis EN 61000-4-6
  • Calibration certificate included for frequency measurement
  • Housing material Anodised aluminium
  • Weight 170 g, app.
  • Accessories Mating connector for Flow and Temperatire, RFID Tag, optional Accessories see separate data sheet

Download